Pop-Up Drainage Emitter with Elbow for 3 in. Drain Pipes, Spring Loaded, Green Plastic

SKU: 321

The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) connects to 3 in. Triple Wall Pipe
Pop-Up Drainage Emitter with Elbow for 3 in. Sewer and Drain Pipes, Green Plastic (NDS 321)
The 3 in. Pop-Up Drainage Emitter connects to the 3 in. Elbow (NDS 321) for a secure fit
Bottom View of the 3 in. & 4 in. Pop-Up Drainage Emitter (NDS 420, NDS 430, NDS 421, NDS 321)
Closeup View of the spring-loaded design fully opened on the Pop-Up Drainage Emitter (NDS 420, NDS 430, NDS 421, NDS 321)
Weep hole in elbow fitting allows leftover water to exit in the Pop-Up Drainage Emitter with Elbow (NDS 322*, NDS 422*, NDS 321, NDS 421); PVC 90° elbow, connects 4 in. Sewer and Drain pipes, Hub X Hub connection
The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) connects to 3 in. S&D pipe
The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) spring-loaded cap pops up as high as 1 in.
Top raises up as excess water releases with the 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321)
The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) lays flat when closed
Closeup View of the spring-loaded design partially open on the Pop-Up Drainage Emitter (NDS 420, NDS 430, NDS 421, NDS 321)
The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) connects to 3 in. Triple Wall Pipe
Pop-Up Drainage Emitter with Elbow for 3 in. Sewer and Drain Pipes, Green Plastic (NDS 321)
The 3 in. Pop-Up Drainage Emitter connects to the 3 in. Elbow (NDS 321) for a secure fit
Bottom View of the 3 in. & 4 in. Pop-Up Drainage Emitter (NDS 420, NDS 430, NDS 421, NDS 321)
Closeup View of the spring-loaded design fully opened on the Pop-Up Drainage Emitter (NDS 420, NDS 430, NDS 421, NDS 321)
Weep hole in elbow fitting allows leftover water to exit in the Pop-Up Drainage Emitter with Elbow (NDS 322*, NDS 422*, NDS 321, NDS 421); PVC 90° elbow, connects 4 in. Sewer and Drain pipes, Hub X Hub connection
The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) connects to 3 in. S&D pipe
The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) spring-loaded cap pops up as high as 1 in.
Top raises up as excess water releases with the 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321)
The 3 in. Pop-Up Drainage Emitter with Elbow (NDS 321) lays flat when closed
Closeup View of the spring-loaded design partially open on the Pop-Up Drainage Emitter (NDS 420, NDS 430, NDS 421, NDS 321)

Discharge collected water that flows downstream to the Pop-Up Drainage Emitter as a point of release. As water pressure builds, the spring-loaded cap “pops up” as high as 1 in., disperses water at up to 56 GPM, then automatically retracts once the flow diminishes. Cap stays closed when not in use to prevent debris and rodents from entering and potentially clogging the drainage system. Weep hole at bottom of elbow drains out water left in pipes to prevent stagnation or freezing in cold weather. The Pop-Up Emitter with Elbow connects to 3 in. sewer and drain pipe and 3 in. triple-wall pipe for a soil-tight. fit. Cap and cover made of high-density polyethylene (HDPE); elbow is made of polyvinyl chloride (PVC) Pop-Up Drainage Emitters are part of a complete drainage system used for stormwater management. They work with pipes, catch basin drains, channel drains, trench drains, and drain grates that filter, capture, and convey excess water to drain pipes; the pipes carry the water downstream to discharge with a Pop-Up Emitter, or to percolate into the ground with a dry well or infiltration trench.

Applications:

  • Provides a downstream point of release for water collected upstream
  • Install the Pop-Up Drainage Emitter at the lowest point in the drainage system; place in areas away from buildings, landscapes, and poor drainage areas
  • Works with a complete drainage system to release collected stormwater runoff and standing water to a discharge point before it causes costly property damage

Features:

  • Spring-loaded cap on cover pops up as high as 1 in. once water pressure builds and closes as flow diminishes; when not in use, cap stays closed to keep debris and rodents out of drain
  • Flange design prevents grass from growing over the cover
  • Small weep hole in elbow drains out any water in the pipe to prevent stagnation or freezing in cold weather
  • Flat profile design reduces trip hazard posed by open drain; closed position keeps emitter flush to the ground and safe from lawn mower blades
  • Rounded contours on interior edges reduce the potential for clogging and internal ribs provide durability and strength

Literature & Resources

Videos

Submit Your Design
NDS DesignWorx® Team is there to help with preparation of submittal drawings and specs. Call us at 888-825-4716 or click below.
Request a Quote
Need to submit a bid package? Let NDS Project Specialists eliminate the guesswork and accurately quote your project for you.

Have Questions? Need Help? Want to Know More?

Helpful Customer Support

Have Questions? Need Help? Want to Know More?

No questions are too big or small. Find out how NDS solutions experts can help you solve your water management problems. Call 800-726-1994 or contact us by clicking below.

Contact Us