PRODUCTS USED
Design flow was set at 20,000 GPD at an average strength of 300 mg/L of both BOD and TSS. The system can handle the average daily flow’s fluctuation over a range of 50% to 100% of the design flow. ECOPOD media was contained within customized stainless steel reactor boxes, and the kits were installed in pre-constructed concrete tanks. ECOPODs were shipped directly to the site complete and ready for installation, consisting of component equipment required for efficient and proper system operation.
A total of five (5) 5,000-gallon reactor tanks were installed, each housing an ECOPOD E400 unit capable of treating 4,000 GPD to an effluent level below 20 mg/L each BOD and TSS. The reactor tanks were preceded by a series of two (2) 5,000 gallon primary tanks. A spray disposal system was also supplied by Infiltrator, complete with effluent pumps, spray heads, tubing, controls, and all necessary valves and fittings. Concrete tanks supplied by a local precaster.