18 in. High StormChamber® Systems

Capture large volumes of stormwater runoff with a smaller footprint than traditional underground systems with the StormChamber® system. 18 in. high arched modular stormwater chambers can be laid out in unique configurations to fit job site requirements, and stacked to increase storage capacity while maintaining usable space above ground.

Key Features

  • Holds significant volume compared to other same size stormwater chambers on the market
  • Minimum installed storage for start unit 48 cu.ft., middle unit 43 cu.ft., end unit 48 cu.ft., closed unit 70 cu.ft.
  • Internal chamber volume start unit 24 cu.ft 24 cu.ft., middle unit 23 cu.ft., end unit 24 cu.ft., closed unit 25 cu.ft.
  • Designed for strength due to thermoformed high-density weight polyethylene (HMWPE) material; withstands extreme environments, and exceeds the AASHTO H-20 design load
  • Simple install internal crossover eliminates expensive header pipe manifold system; modular chambers overlap to form rows; side portal feed connects rows, provides greater flexibility and hydraulic design
  • Easy maintenance saves water and money by removing sediments from SedimenTrap™ devices using an air vacuum truck rather than jet cleaning with water
  • Long life expectancy designed by engineers, ecologists, and biologists to ensure maximum efficiency and effectiveness

Applications

  • Detains, infiltrates, and conveys stormwater runoff; modular system maximizes storage volume with a smaller footprint than traditional concrete and stone systems; easy to maintain
  • Works in commercial, industrial, municipal, and residential settings to manage stormwater runoff; ideal for installing underneath parking lots, playing fields, and landscapes
  • As part of a complete stormwater management system, the StormChamber® system works with a capture device or drainage inlet to detain, infiltrate, and convey collected stormwater

Installation & Maintenance

  1. Excavate trench
  2. Line walls with non-woven filter fabric
  3. Add SedimenTrap™ devices
  4. Add hard stone & woven stabilization fabric
  5. Place overlapping chambers into trench & screw together
  6. Cut portal holes for pipe (read installation manual for details)
  • Use riser pipe connected to SedimenTrap™ device as an observation well and inspect with flashlight and stick
  • Air vacuum when deposits approach within 6 in. of the invert height of connecting pipes between StormChamber®  rows
  • Determine maintenance schedule with quarterly inspections and logbook
  • Maintenance without SedimenTrap device is done with water jet method

Materials & Sustainability

  • StormChamber® unit is made of thermoformed high-density weight polyethylene (HMWPE)
  • StormChamber® systems are made in the USA

Product Models

Filter results

Family
Shape

4 products

    Part Number
    (click for more info)
    Description
    SC-1820-E-O StormChamber® Stormwater Chamber, 18 in. High, End Unit, Orange
    SC-1820-C-O StormChamber® Stormwater Chamber, 18 in. High, Closed Unit, Orange
    SC-1820-M-O StormChamber® Stormwater Chamber, 18 in. High, Middle Unit, Orange
    SC-1820-S-O StormChamber® Stormwater Chamber, 18 in. High, Start Unit, Orange

    Specifications & Documents