Barracuda S6 Max Concrete Standard Detail

Filename:
Barracuda S6 Max Concrete Standard Detail.pdf

Barracuda S6 Max Concrete Standard Detail

This document is the Barracuda S6 Max Concrete Standard Detail. The stormwater separator plan view and section views with dimensions included.

The plan view shows the frame and cover, inlet pipe, outlet pipe and WQU-Barracuda S6.

The section view A-A shows the frame and cover, asphalt installation, integrated internal weir, turf installation, deflector plate, bowl, fin array and Barracuda Max bowl insert.

The section view B-B shows the integrated internal weir, inlet/outlet pipe, deflector plate, bowl, fin array and Barracuda Max bowl insert.

A table for Barracuda Max S6 lists values for unit ID, peak flow rate and treatment flow rate.